NSN 5930-00-405-0567
Part Details | PRESSURE SWITCH
5930-00-405-0567 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 611GCE340S, 2601766, 5930-00-405-0567, 00-405-0567, 5930004050567, 004050567
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | APR 07, 1971 | 00-405-0567 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-405-0567
Part Number | Cage Code | Manufacturer |
---|---|---|
611GCE340S | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
2601766 | 30003 | NAVAL AIR SYSTEMS COMMAND MANAGEDORIGINAL DESIGN ACTIVITY NOT |
Technical Data | NSN 5930-00-405-0567
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 7 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 3.750 INCHES NOMINAL |
WIDTH ACROSS FLATS | 0.684 INCHES MINIMUM AND 0.691 INCHES MAXIMUM |
BODY DIAMETER | 1.437 INCHES NOMINAL |
OVERALL DIAMETER | 1.875 INCHES NOMINAL |
PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BD4.00 DIFFERENTIAL POINT MINIMUM AND BD6.00 DIFFERENTIAL POINT MAXIMUM |
OPERATING TEMP RATING | 20.0 DEG FAHRENHEIT MINIMUM AND 120.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
PROOF PRESSURE | 250.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | INLET CONNECTION |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |