NSN 5930-00-409-3200
Part Details | THERMOSTATIC SWITCH
5930-00-409-3200 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 30002612, 3000-26-12, 3197014, 319701-4, 2153232, 21532-32, 5930-00-409-3200, 00-409-3200, 5930004093200, 004093200
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 28, 1972 | 00-409-3200 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-409-3200
Part Number | Cage Code | Manufacturer |
---|---|---|
3000-26-12 | 14604 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
319701-4 | 80020 | NAVAL AIR WARFARE CENTER AIRCRAFTDIVISION CODE 4.8.8.0.0.B BLDG 148-2 |
21532-32 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
Technical Data | NSN 5930-00-409-3200
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 4 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 1.281 INCHES NOMINAL |
OVERALL WIDTH | 0.391 INCHES MINIMUM AND 0.421 INCHES MAXIMUM |
BODY HEIGHT | 0.803 INCHES MAXIMUM |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | DECREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | BRACKET |