NSN 5930-00-409-3485

Part Details | PRESSURE SWITCH

5930-00-409-3485 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 130P25M0DIFIED, 130P2-5M0DIFIED, 2668382050, 266-8382-050, 5930-00-409-3485, 00-409-3485, 5930004093485, 004093485

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 15, 197000-409-348500206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL

Cross Reference | NSN 5930-00-409-3485
Part Number Cage Code Manufacturer
130P2-5M0DIFIED96502HENRY G DIETZ CO INC
266-8382-05013499ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS
Technical Data | NSN 5930-00-409-3485
Characteristic Specifications
STYLE DESIGNATOR7 CYLINDRICAL
OVERALL LENGTH5.000 INCHES NOMINAL
OVERALL HEIGHT9.000 INCHES NOMINAL
OVERALL WIDTH4.625 INCHES NOMINAL
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE+0.15 TO +2.00 ACTUATION POINT INCHES OF WATER AND +0.15 TO +2.00 DEACTUATION POINT INCHES OF WATER
CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW
CONTACT STIMULUS RATINGAR0.65 ACTUATION POINT NOMINAL AND AR0.55 DEACTUATION POINT NOMINAL AND AR0.10 DIFFERENTIAL POINT NOMINAL
OPERATING TEMP RATING-10.0 DEG CELSIUS MINIMUM AND 55.0 DEG CELSIUS MAXIMUM
MEDIA FOR WHICH DESIGNED LIQUID
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD THREADED STUD
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS2.250 INCHES NOMINAL