NSN 5930-00-410-5425
Part Details | ROTARY SWITCH
5930-00-410-5425 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 42M360415S, 42M36-04-1-5S, 42M3604105S, 42M36-04-1-05S, M378640483, M3786/4-0483, MILS37864, MIL-S-3786/4, MILDTL37864, MIL-DTL-3786/4, 66A5A613, 66A5A6-13, 5930-00-410-5425, 00-410-5425, 5930004105425, 004105425
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 11, 1969 | 00-410-5425 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-410-5425
Part Number | Cage Code | Manufacturer |
---|---|---|
42M36-04-1-5S | 81073 | GRAYHILL, INC |
42M36-04-1-05S | 81073 | GRAYHILL, INC |
M3786/4-0483 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-S-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-DTL-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
66A5A6-13 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
Technical Data | NSN 5930-00-410-5425
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
OVERALL LENGTH | 2.937 INCHES NOMINAL |
OVERALL DIAMETER | 1.000 INCHES MINIMUM AND 1.306 INCHES MAXIMUM |
INDIVIDUAL SECTION QUANTITY | 4 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
TERMINAL TYPE | TAB, SOLDER LUG |
TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--3786 TO 4 GOVERNMENT SPECIFICATION |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
OPERATING TEMP RANGE | -65.0 TO +85.0 DEG CELSIUS |