NSN 5930-00-411-3905
Part Details | LIQUID LEVEL SWITCH
5930-00-411-3905 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.
Alternate Parts: F2061, F206-1, F2061, F206-1, 309723, 309723, 5930-00-411-3905, 00-411-3905, 5930004113905, 004113905
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 27, 1969 | 00-411-3905 | 37187 ( SWITCH, LIQUID LEVEL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-411-3905
Part Number | Cage Code | Manufacturer |
---|---|---|
F206-1 | 53655 | AVOX SYSTEMS INC. |
F206-1 | 83945 | B E AEROSPACE INCSERVICES DIV |
309723 | 33654 | HOWDEN FLUID SYSTEMS |
309723 | 58163 | MEGGITT (NORTH HOLLYWOOD), INC.DBA MEGGITT CONTROL SYSTEMS |
Technical Data | NSN 5930-00-411-3905
Characteristic | Specifications |
---|---|
DC VOLTAGE RATING | A28.0 VOLTS |
INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES RESISTIVE LOAD |
CONTACT ARRANGEMENT | SINGLE POLE SINGLE THROW NORMALLY CLOSED |
RELAY | NOT INCLUDED |
LIQUID TYPE FOR WHICH DESIGNED | HYDRAULIC FLUID |
OPERATING TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
ACTUATION METHOD | BUOYANCY |
FLOAT QUANTITY | 1 |
FLOAT EFFECTIVE TRAVEL | 3.000 INCHES MAXIMUM |
MOUNTING POSITION | VERTICAL |
MOUNTING METHOD | FLANGE |
MOUNTING DIMENSIONS | MTD BY SIX 0.190 IN. DIA HOLES EQUALLY SPACED ON 1.99 IN. BOLT CIRCLE |
OVERALL LENGTH | 6.315 INCHES NOMINAL |
OVERALL DIAMETER | 2.500 INCHES NOMINAL |
TANK INSERTION LENGTH | 5.530 INCHES MAXIMUM |