Part Details | ROTARY SWITCH
5930-00-487-6829 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 44HS300318N, 44HS30-03-1-8N, 4M30F13N8, 4M30F1-3N8, M378645051, M3786/4-5051, M3786135051, M3786/13-5051, MILS37864, MIL-S-3786/4, MILDTL37864, MIL-DTL-3786/4, 5930-00-487-6829, 00-487-6829, 5930004876829, 004876829
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUN 22, 1974 | 00-487-6829 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT
Cross Reference | NSN 5930-00-487-6829
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 44HS30-03-1-8N | 81073 | GRAYHILL, INC |
| 4M30F1-3N8 | 91812 | JANCO CORPORATIONDBA ESTERLINE MASON |
| M3786/4-5051 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M3786/13-5051 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-S-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-DTL-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-487-6829
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
| OVERALL LENGTH | 2.427 INCHES MINIMUM AND 2.755 INCHES MAXIMUM |
| OVERALL DIAMETER | 1.100 INCHES MINIMUM AND 1.306 INCHES MAXIMUM |
| INDIVIDUAL SECTION QUANTITY | 3 |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
| TERMINAL TYPE | TAB, SOLDER LUG |
| TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| OPERATING TEMP RANGE | -65.0 TO +125.0 DEG CELSIUS |