NSN 5930-00-496-4649
Part Details | PRESSURE SWITCH
5930-00-496-4649 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 75180991110, 506105482, 506105-48-2, 506105482, 506105-48-2, 75180991110, 75180991110, 2668388020, 266-8388-020, 2668388020, 266-8388-020, 5930-00-496-4649, 00-496-4649, 5930004964649, 004964649
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUN 27, 1974 | 00-496-4649 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL
Cross Reference | NSN 5930-00-496-4649
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 75180991110 | 58918 | AEROSPACE CONTROL PRODUCTS, INC. |
| 506105-48-2 | 08664 | BRISTOL BABCOCK INCINSTRUMENTS-SYSTEMS DIV |
| 506105-48-2 | 1CFF7 | BRISTOL INC.DBA REMOTE AUTOMATION SOLUTIONS DIV |
| 75180991110 | 99251 | CARLETON LIFE SUPPORT SYSTEMS INC.DBA COBHAM MISSION SYSTEM |
| 75180991110 | 70192 | GAP INSTRUMENT CORPGORN DIV |
| 266-8388-020 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
| 266-8388-020 | 95105 | ROCKWELL COLLINS, INC.DIV GOVERNMENT SYSTEMS - DALLAS |
Technical Data | NSN 5930-00-496-4649
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 1 CYLINDRICAL |
| OVERALL LENGTH | 2.031 INCHES MAXIMUM |
| WIDTH ACROSS FLATS | 0.625 INCHES NOMINAL |
| BODY LENGTH | 1.531 INCHES MAXIMUM |
| OVERALL DIAMETER | 1.015 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | ABSOLUTE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | ACABC9.35 ACTUATION POINT MAXIMUM |
| OPERATING TEMP RATING | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 30.00 POUNDS PER SQUARE INCH ABSOLUTE |
| TERMINAL TYPE | WIRE HOOK |
| MOUNTING METHOD | INLET CONNECTION AND TERMINAL |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |