NSN 5930-00-501-4770
Part Details | PRESSURE SWITCH
5930-00-501-4770 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 44A127, 650376, 100657, 100-657, 5930-00-501-4770, 00-501-4770, 5930005014770, 005014770
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-501-4770 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-501-4770
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 44A127 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| 650376 | 82577 | RAYTHEON COMPANYDBA RAYTHEON |
| 100-657 | 81833 | TRANSDIGM, INC.DBA AEROCONTROLEX |
Technical Data | NSN 5930-00-501-4770
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 5 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 3.000 INCHES MAXIMUM |
| OVERALL HEIGHT | 3.030 INCHES MAXIMUM |
| OVERALL WIDTH | 2.500 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADC DEACTUATION POINT AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | ACABC26.50 ACTUATION POINT MAXIMUM AND ADABC28.50 DEACTUATION POINT AND AKABC2.00 DIFFERENTIAL POINT |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | BASE AND THREADED HOLE |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.495 INCHES MINIMUM AND 1.505 INCHES MAXIMUM |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.495 INCHES MINIMUM AND 1.505 INCHES MAXIMUM |
| FEATURES PROVIDED | AUTOMATIC RESET |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |