NSN 5930-00-519-4783
Part Details | PRESSURE SWITCH
5930-00-519-4783 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 40064, 40064, 5930-00-519-4783, 00-519-4783, 5930005194783, 005194783
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-519-4783 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL
Cross Reference | NSN 5930-00-519-4783
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 40064 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| 40064 | 98505 | HYDRA-ELECTRIC COMPANY |
Technical Data | NSN 5930-00-519-4783
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 6 CYLINDRICAL |
| OVERALL LENGTH | 2.930 INCHES NOMINAL |
| OVERALL WIDTH | 2.620 INCHES NOMINAL |
| BODY DIAMETER | 2.300 INCHES NOMINAL |
| BODY LENGTH | 2.060 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADC DEACTUATION POINT AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | ACABB10.00 ACTUATION POINT MAXIMUM AND ADABB12.00 DEACTUATION POINT AND AKABB2.00 DIFFERENTIAL POINT |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH GAGE |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES MINIMUM AND 0.233 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.125 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.125 INCHES NOMINAL |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |