NSN 5930-00-538-0466
Part Details | PRESSURE SWITCH
5930-00-538-0466 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: G270, 5930-00-538-0466, 00-538-0466, 5930005380466, 005380466
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-538-0466 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-538-0466
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| G270 | 32242 | JOHNSON CONTROLS, INC.DBA JOHNSON CONTROLS |
Technical Data | NSN 5930-00-538-0466
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 4.000 INCHES NOMINAL |
| OVERALL HEIGHT | 4.750 INCHES NOMINAL |
| OVERALL WIDTH | 0.750 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACB ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +3.00 TO +35.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| TERMINAL TYPE | TAB W/SCREW |
| MOUNTING METHOD | INLET CONNECTION |
| FEATURES PROVIDED | CALIBRATED SCALE |