NSN 5930-00-660-3648

Part Details | THERMOSTATIC SWITCH

5930-00-660-3648 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 22210NN2221458, 222-10NN2221458, 22210NN2221011, 222-10NN2221011, TS1420, 47606725 ITEM 5, 476-06725 ITEM 5, 02509508, 025-09508, S62023201499, S6202-3201499, NF920040, NF9-20040, 5930-00-660-3648, 00-660-3648, 5930006603648, 006603648

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-660-364800451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-660-3648
Part Number Cage Code Manufacturer
222-10NN222145819278DETROIT SWITCH, INC.
222-10NN222101119278DETROIT SWITCH, INC.
TS142019278DETROIT SWITCH, INC.
476-06725 ITEM 566935JOHNSON CONTROLS NAVY SYSTEMS, LLC
025-0950866935JOHNSON CONTROLS NAVY SYSTEMS, LLC
S6202-320149980064NAVAL SHIP SYSTEMS COMMAND
NF9-2004088234UNITED ELECTRIC CONTROLS COMPANY
Technical Data | NSN 5930-00-660-3648
Characteristic Specifications
STYLE DESIGNATOR5 CYLINDRICAL W/FLANGE
OVERALL LENGTH5.188 INCHES NOMINAL
OVERALL HEIGHT5.937 INCHES NOMINAL
OVERALL WIDTH2.812 INCHES NOMINAL
BODY HEIGHT2.750 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+0.00 TO +60.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL ACTUATION POINT SCREW
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE
CAPILLARY TUBE LENGTH240.000 INCHES NOMINAL
TERMINAL TYPE SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.656 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION EXPLOSION PROOF AND WATERTIGHT AND DUSTPROOF