NSN 5930-00-691-2718
Part Details | PRESSURE SWITCH
5930-00-691-2718 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 7742869P001, 7742869P001, 269525, 2695-25, 26950030, 2695-0030, 5930-00-691-2718, 00-691-2718, 5930006912718, 006912718
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-691-2718 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-691-2718
Part Number | Cage Code | Manufacturer |
---|---|---|
7742869P001 | 24446 | GENERAL ELECTRIC COMPANY |
7742869P001 | 03538 | LOCKHEED MARTIN CORPORATIONDIV RMS |
2695-25 | 90800 | ROMAC INDUSTRIES, INC.DBA HAYS FLUID CONTROL DIVISION |
2695-0030 | 90800 | ROMAC INDUSTRIES, INC.DBA HAYS FLUID CONTROL DIVISION |
Technical Data | NSN 5930-00-691-2718
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 4.250 INCHES NOMINAL |
OVERALL WIDTH | 3.500 INCHES NOMINAL |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AM5.25 ACTUATION POINT NOMINAL AND AM5.25 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |