NSN 5930-00-704-9786

Part Details | PRESSURE SWITCH

5930-00-704-9786 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 506201023, 506201-02-3, C20211, C2021-1, 506201023, 506201-02-3, 92D3, 21517, 21-517, 5930-00-704-9786, 00-704-9786, 5930007049786, 007049786

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-704-978600206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-00-704-9786
Part Number Cage Code Manufacturer
506201-02-308664BRISTOL BABCOCK INCINSTRUMENTS-SYSTEMS DIV
C2021-108664BRISTOL BABCOCK INCINSTRUMENTS-SYSTEMS DIV
506201-02-31CFF7BRISTOL INC.DBA REMOTE AUTOMATION SOLUTIONS DIV
92D309049CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY
21-51799167HAMILTON SUNDSTRAND CORPORATION
Technical Data | NSN 5930-00-704-9786
Characteristic Specifications
STYLE DESIGNATOR7 RECTANGULAR
OVERALL LENGTH1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM
BODY LENGTH1.660 INCHES MINIMUM AND 1.790 INCHES MAXIMUM
OVERALL DIAMETER1.296 INCHES MINIMUM AND 1.328 INCHES MAXIMUM
PRESSURE SWITCH TYPE DIFFERENTIAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE AND ADC DEACTUATION POINT
CONTACT STIMULUS RATINGACABB5.50 ACTUATION POINT MAXIMUM AND ADABB1.50 DEACTUATION POINT
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
PROOF PRESSURE80.00 POUNDS PER SQUARE INCH GAGE
TERMINAL TYPE WIRE LOOP
MOUNTING METHOD THREADED STUD
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.678 INCHES MINIMUM AND 0.698 INCHES MAXIMUM