NSN 5930-00-736-4085
Part Details | PRESSURE SWITCH
5930-00-736-4085 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: MF62015, MF620-15, 2040616101, 204-061-610-1, 204061610001, 204-061-610-001, GP800042, GP8000-42, 1G56, GP800042, GP8000-42, 5930-00-736-4085, 00-736-4085, 5930007364085, 007364085
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-736-4085 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL
Cross Reference | NSN 5930-00-736-4085
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MF620-15 | 53655 | AVOX SYSTEMS INC. |
| 204-061-610-1 | 97499 | BELL HELICOPTER TEXTRON INC.DBA BELL HELICOPTER |
| 204-061-610-001 | 97499 | BELL HELICOPTER TEXTRON INC.DBA BELL HELICOPTER |
| GP8000-42 | 99251 | CARLETON LIFE SUPPORT SYSTEMS INC.DBA COBHAM MISSION SYSTEM |
| 1G56 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| GP8000-42 | 70192 | GAP INSTRUMENT CORPGORN DIV |
Technical Data | NSN 5930-00-736-4085
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 2 CYLINDRICAL |
| OVERALL LENGTH | 3.484 INCHES NOMINAL |
| OVERALL HEIGHT | 2.620 INCHES NOMINAL |
| BODY DIAMETER | 2.625 INCHES NOMINAL |
| BODY LENGTH | 2.060 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADC DEACTUATION POINT AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | ACABD7.50 ACTUATION POINT MAXIMUM AND ADABD5.50 DEACTUATION POINT |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 260.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | BRACKET |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |
| SENSING ELEMENT BURST PRESSURE | 180.00 POUNDS PER SQUARE INCH |