NSN 5930-00-755-3316
Part Details | PRESSURE SWITCH
5930-00-755-3316 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: R6607212, R6607-2-12, 1581, S6135203880, S6135-20388-0, 5930-00-755-3316, 00-755-3316, 5930007553316, 007553316
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1962 | 00-755-3316 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-755-3316
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| R6607-2-12 | 02750 | EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION |
| 1581 | 02005 | HAYDON KERK MOTION SOLUTIONS, INC.DIV HAYDON KERK |
| S6135-20388-0 | 78286 | SIKORSKY AIRCRAFT CORPORATIONDBA SIKORSKY |
Technical Data | NSN 5930-00-755-3316
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 7 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 3.000 INCHES MAXIMUM |
| BODY DIAMETER | 1.375 INCHES MAXIMUM |
| BODY LENGTH | 2.125 INCHES NOMINAL |
| OVERALL DIAMETER | 1.375 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACE ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +6.00 TO +25.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW |
| CONTACT STIMULUS RATING | ACABD7.00 ACTUATION POINT MAXIMUM |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 1000.00 POUNDS PER SQUARE INCH GAGE |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.201 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.500 INCHES NOMINAL |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| SENSING ELEMENT BURST PRESSURE | 2500.00 POUNDS PER SQUARE INCH GAGE |