NSN 5930-00-781-1405
Part Details | PRESSURE SWITCH
5930-00-781-1405 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: Q460039, Q4600-39, 96531HF3, 9653-1HF3, 96531WAF3, 9653-1-WA-F3, 96531HF35000PSI, 9653-1HF3-5000PSI, Q460039, Q4600-39, 5930-00-781-1405, 00-781-1405, 5930007811405, 007811405
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAR 22, 1968 | 00-781-1405 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-781-1405
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| Q4600-39 | 05172 | AAI CORPORATIONDIV MISSISSIPPI OPERATIONS |
| 9653-1HF3 | 89326 | BARKSDALE INC |
| 9653-1-WA-F3 | 89326 | BARKSDALE INC |
| 9653-1HF3-5000PSI | 89326 | BARKSDALE INC |
| Q4600-39 | 06659 | TESTEK, LLC |
Technical Data | NSN 5930-00-781-1405
| Characteristic | Specifications |
|---|---|
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADE DEACTUATION POINT AND ACE ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +0.00 TO +5000.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | BRACKET |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.000 INCHES NOMINAL |