NSN 5930-00-843-1807

Part Details | PRESSURE SWITCH

5930-00-843-1807 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 53174A, 8030001, 53174A, 53174A, 772032, 15264, 772032, 5930-00-843-1807, 00-843-1807, 5930008431807, 008431807

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196200-843-180700206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-843-1807
Part Number Cage Code Manufacturer
53174A89330CENTURY GEOPHYSICAL CORP
803000154208ELECTRO NATIONAL CORPORATIONDBA ENC
53174A54208ELECTRO NATIONAL CORPORATIONDBA ENC
53174A00214HATHAWAY MOTION CONTROL CORP
77203298505HYDRA-ELECTRIC COMPANY
1526498505HYDRA-ELECTRIC COMPANY
77203210001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
Technical Data | NSN 5930-00-843-1807
Characteristic Specifications
STYLE DESIGNATOR8 CYLINDRICAL W/FLANGE
BODY LENGTH2.438 INCHES NOMINAL
OVERALL DIAMETER1.188 INCHES NOMINAL
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGBB1100.00 ACTUATION POINT NOMINAL AND BB1100.00 DEACTUATION POINT NOMINAL
OPERATING TEMP RATING-20.0 DEG FAHRENHEIT MINIMUM AND 165.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
PROOF PRESSURE4500.00 POUNDS PER SQUARE INCH
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD INLET CONNECTION
FEATURES PROVIDED ELECTRICAL ACCESS PORT
SENSING ELEMENT BURST PRESSURE7500.00 POUNDS PER SQUARE INCH GAGE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION WEATHERPROOF