NSN 5930-00-859-0240
Part Details | THERMOSTATIC SWITCH
5930-00-859-0240 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: VE2102SET110DEGFP0RM3DEGFCR, 37654950001, 37654950-001, VE2064SET110DEGFCR, VE2064, 67240303, 672403-03, 5930-00-859-0240, 00-859-0240, 5930008590240, 008590240
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | APR 21, 1972 | 00-859-0240 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-00-859-0240
Part Number | Cage Code | Manufacturer |
---|---|---|
VE2102SET110DEGFP0RM3DEGFCR | 12012 | MINARIK CORPORATIONDBA MINARIK AUTOMATION & CONTROL |
37654950-001 | 08783 | RAYTHEON CO |
VE2064SET110DEGFCR | 93929 | SPX CORPORATIONDBA RADIODETECTION |
VE2064 | 93929 | SPX CORPORATIONDBA RADIODETECTION |
672403-03 | K1182 | THALES UK LIMITED DBA THALES UKLTDTRAINING AND SIMULATION |
Technical Data | NSN 5930-00-859-0240
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | RECTANGULAR |
OVERALL LENGTH | 1.250 INCHES NOMINAL |
OVERALL HEIGHT | 0.688 INCHES NOMINAL |
OVERALL WIDTH | 0.375 INCHES NOMINAL |
BODY LENGTH | 0.750 INCHES NOMINAL |
BODY WIDTH | 0.250 INCHES NOMINAL |
BODY HEIGHT | 0.453 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF110.00 ACTUATION POINT NOMINAL AND AF107.00 DEACTUATION POINT NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | BRACKET |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPTIGHT |