NSN 5930-00-911-8427
Part Details | THERMOSTATIC SWITCH
5930-00-911-8427 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 2427640, L507001432, 24276402, 2427640-2, 5930-00-911-8427, 00-911-8427, 5930009118427, 009118427
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1960 | 00-911-8427 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-911-8427
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2427640 | 00906 | BARD ELECTRONICS INC |
| L507001432 | 36090 | LOCKHEED MARTIN LIBRASCOPECORP |
| 2427640-2 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
Technical Data | NSN 5930-00-911-8427
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 3.306 INCHES NOMINAL |
| BODY DIAMETER | 0.500 INCHES MAXIMUM |
| BODY LENGTH | 2.156 INCHES MAXIMUM |
| OVERALL DIAMETER | 0.550 INCHES MAXIMUM |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADE DEACTUATION POINT AND ACE ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +0.00 TO +185.00 ACTUATION POINT DEGREES FAHRENHEIT AND +0.00 TO +185.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| CONTACT STIMULUS RATING | ACAAF140.00 ACTUATION POINT MAXIMUM AND ADAAF137.00 DEACTUATION POINT |
| OPERATING TEMP RATING | -0.0 DEG FAHRENHEIT MINIMUM AND 185.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | IMMERSION WELL |
| FEATURES PROVIDED | TAMPER PROOF CAP |