NSN 5930-01-011-3607

Part Details | PRESSURE SWITCH

5930-01-011-3607 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: DPS300, DPS-300, 5930-01-011-3607, 01-011-3607, 5930010113607, 010113607

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 21, 197501-011-360700206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL

Cross Reference | NSN 5930-01-011-3607
Part Number Cage Code Manufacturer
DPS-30054167KOENIG-PRETEMPCO INC
Technical Data | NSN 5930-01-011-3607
Characteristic Specifications
STYLE DESIGNATOR8 CYLINDRICAL
OVERALL LENGTH7.250 INCHES NOMINAL
OVERALL HEIGHT3.000 INCHES NOMINAL
OVERALL WIDTH5.250 INCHES NOMINAL
BODY LENGTH3.000 INCHES NOMINAL
PRESSURE SWITCH TYPE DIFFERENTIAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE+0.00 TO +20.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.00 TO +20.00 DEACTUATION POINT POUNDS PER SQUARE INCH
CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT KNOB AND INTERNAL DEACTUATION POINT KNOB
CONTACT STIMULUS RATINGBB0.00 DEACTUATION POINT MINIMUM AND BB20.00 DEACTUATION POINT MAXIMUM AND BB0.10 DIFFERENTIAL POINT MINIMUM AND BB5.00 DIFFERENTIAL POINT MAXIMUM AND BB48.00 ACTUATION POINT MINIMUM
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 180.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED LIQUID
PROOF PRESSURE300.00 POUNDS PER SQUARE INCH
TERMINAL TYPE SCREW
MOUNTING METHOD BRACKET
MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS4.750 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS2.000 INCHES NOMINAL
SENSING ELEMENT BURST PRESSURE600.00 POUNDS PER SQUARE INCH