NSN 5930-01-011-3607
Part Details | PRESSURE SWITCH
5930-01-011-3607 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: DPS300, DPS-300, 5930-01-011-3607, 01-011-3607, 5930010113607, 010113607
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | OCT 21, 1975 | 01-011-3607 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-01-011-3607
Part Number | Cage Code | Manufacturer |
---|---|---|
DPS-300 | 54167 | KOENIG-PRETEMPCO INC |
Technical Data | NSN 5930-01-011-3607
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 8 CYLINDRICAL |
OVERALL LENGTH | 7.250 INCHES NOMINAL |
OVERALL HEIGHT | 3.000 INCHES NOMINAL |
OVERALL WIDTH | 5.250 INCHES NOMINAL |
BODY LENGTH | 3.000 INCHES NOMINAL |
PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ADJUSTMENT RANGE | +0.00 TO +20.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.00 TO +20.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT KNOB AND INTERNAL DEACTUATION POINT KNOB |
CONTACT STIMULUS RATING | BB0.00 DEACTUATION POINT MINIMUM AND BB20.00 DEACTUATION POINT MAXIMUM AND BB0.10 DIFFERENTIAL POINT MINIMUM AND BB5.00 DIFFERENTIAL POINT MAXIMUM AND BB48.00 ACTUATION POINT MINIMUM |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 180.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
PROOF PRESSURE | 300.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | SCREW |
MOUNTING METHOD | BRACKET |
MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.750 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.000 INCHES NOMINAL |
SENSING ELEMENT BURST PRESSURE | 600.00 POUNDS PER SQUARE INCH |