NSN 5930-01-014-9532
Part Details | THERMOSTATIC SWITCH
5930-01-014-9532 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 5011002001133, 5011-002-001-133, P4171A, P-4171A, 25 703 01S, 25 703 01-S, 230989, C184336, C-18433-6, 501121, 5011-2-1, 5930-01-014-9532, 01-014-9532, 5930010149532, 010149532
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 13, 1976 | 01-014-9532 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-014-9532
Part Number | Cage Code | Manufacturer |
---|---|---|
5011-002-001-133 | 82415 | AIRPAX CORP LLC |
P-4171A | 11568 | GARDNER DENVER INC. |
25 703 01-S | 52845 | KOHLER CO ENGINE PLANT DIV |
230989 | 52845 | KOHLER CO ENGINE PLANT DIV |
C-18433-6 | 75418 | KYSOR INDUSTRIAL CORP |
5011-2-1 | 28340 | PROTECTIVE CONTROLS INC |
Technical Data | NSN 5930-01-014-9532
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 0 CYLINDRICAL W/FLANGE |
OVERALL HEIGHT | 0.594 INCHES NOMINAL |
BODY HEIGHT | 0.375 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF480.00 ACTUATION POINT NOMINAL AND AF440.00 DEACTUATION POINT NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | CLAMP |
SPECIAL FEATURES | SEAL AREA ON TOP OF INSULATOR |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |