NSN 5930-01-026-6843
Part Details | PRESSURE SWITCH
5930-01-026-6843 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 42D299, 160C9509171, 160C950917-1, 160C950917, 5930-01-026-6843, 01-026-6843, 5930010266843, 010266843
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 29, 1976 | 01-026-6843 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL

Cross Reference | NSN 5930-01-026-6843
Part Number | Cage Code | Manufacturer |
---|---|---|
42D299 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
160C950917-1 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS |
160C950917 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS |
Technical Data | NSN 5930-01-026-6843
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 6 CYLINDRICAL |
OVERALL LENGTH | 3.600 INCHES MAXIMUM |
OVERALL WIDTH | 3.600 INCHES MAXIMUM |
BODY DIAMETER | 2.400 INCHES MAXIMUM |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BB4.00 ACTUATION POINT NOMINAL AND BB1.00 DEACTUATION POINT NOMINAL AND BB3.00 DIFFERENTIAL POINT NOMINAL |
MEDIA FOR WHICH DESIGNED | LIQUID |
PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.210 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |
SENSING ELEMENT BURST PRESSURE | 180.00 POUNDS PER SQUARE INCH |