NSN 5930-01-044-9251
Part Details | PRESSURE SWITCH
5930-01-044-9251 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 13220E80741, 13220E8074-1, 675DH958S, 75096, 5930-01-044-9251, 01-044-9251, 5930010449251, 010449251
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 23, 1977 | 01-044-9251 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-044-9251
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 13220E8074-1 | 97403 | CECOM LR CENTER |
| 675DH958S | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| 75096 | 98505 | HYDRA-ELECTRIC COMPANY |
Technical Data | NSN 5930-01-044-9251
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 4.400 INCHES MAXIMUM |
| OVERALL DIAMETER | 5.000 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADB DEACTUATION POINT AND ACB ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +1.50 TO +30.00 ACTUATION POINT INCHES OF WATER AND +0.50 TO +27.00 DEACTUATION POINT INCHES OF WATER |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT HEX NUT AND EXTERNAL ACTUATION POINT HEX NUT |
| OPERATING TEMP RATING | -30.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 15.00 POUNDS PER SQUARE INCH ABSOLUTE |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | THREADED STUD |
| MOUNTING FACILITY PATTERN | THREE POSITION CIRCULAR |
| MOUNTING FACILITY CIRCLE RADIUS | 2.080 INCHES NOMINAL |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE AND ELECTRICAL ACCESS PORT |