NSN 5930-01-046-6942
Part Details | THERMOSTATIC SWITCH
5930-01-046-6942 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 2222586NL, 22210NL2222586, 222-10NL-2222586, NF920022, NF9-20022, 5930-01-046-6942, 01-046-6942, 5930010466942, 010466942
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 21, 1977 | 01-046-6942 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-01-046-6942
Part Number | Cage Code | Manufacturer |
---|---|---|
2222586NL | 19278 | DETROIT SWITCH, INC. |
222-10NL-2222586 | 19278 | DETROIT SWITCH, INC. |
NF9-20022 | 88234 | UNITED ELECTRIC CONTROLS COMPANY |
Technical Data | NSN 5930-01-046-6942
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 3 RECTANGULAR |
OVERALL LENGTH | 4.875 INCHES NOMINAL |
OVERALL HEIGHT | 3.281 INCHES NOMINAL |
OVERALL WIDTH | 2.875 INCHES NOMINAL |
BODY HEIGHT | 2.500 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +140.00 TO +215.00 ACTUATION POINT DEGREES FAHRENHEIT AND +138.00 TO +210.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
OPERATING TEMP RATING | 245.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
BULB LENGTH | 3.625 INCHES NOMINAL |
BULB DIAMETER | 0.688 INCHES NOMINAL |
TERMINAL TYPE | TAB W/SCREW |
MOUNTING METHOD | BRACKET |
MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.750 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
SPECIAL FEATURES | MANUFACTURING PROCESSES AND MATERIALS ARE CRITICAL TO SAFETY OF LIFE AND PROPERTY |
CRITICALITY CODE JUSTIFICATION | FEAT |