NSN 5930-01-051-3305
Part Details | THERMOSTATIC SWITCH
5930-01-051-3305 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 1C2B2, 80015, 5930-01-051-3305, 01-051-3305, 5930010513305, 010513305
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | NOV 27, 1977 | 01-051-3305 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-051-3305
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 1C2B2 | 63325 | VULCAN ELECTRIC COMPANY |
| 80015 | 89564 | VULCAN-HART CORP |
Technical Data | NSN 5930-01-051-3305
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 4.250 INCHES NOMINAL |
| BODY DIAMETER | 0.625 INCHES NOMINAL |
| BODY LENGTH | 2.875 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADE DEACTUATION POINT AND ACE ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +100.00 TO +700.00 ACTUATION POINT DEGREES FAHRENHEIT AND +100.00 TO +700.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| CONTACT STIMULUS RATING | ACAAF250.00 ACTUATION POINT MAXIMUM AND ADAAF245.00 DEACTUATION POINT |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | THREADED BUSHING |