Part Details | THERMOSTATIC SWITCH
5930-01-053-9880 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 22210NN2222392, 222-10NN2222392, 5930-01-053-9880, 01-053-9880, 5930010539880, 010539880
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 13, 1978 | 01-053-9880 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-053-9880
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 222-10NN2222392 | 19278 | DETROIT SWITCH, INC. |
Technical Data | NSN 5930-01-053-9880
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 4.875 INCHES NOMINAL |
| OVERALL WIDTH | 2.625 INCHES NOMINAL |
| BODY HEIGHT | 2.500 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | ADB DEACTUATION POINT AND ACB ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +185.00 TO +250.00 ACTUATION POINT DEGREES FAHRENHEIT AND +183.00 TO +245.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| OPERATING TEMP RATING | 276.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
| CAPILLARY TUBE LENGTH | 128.000 INCHES NOMINAL |
| BULB LENGTH | 6.000 INCHES NOMINAL |
| BULB DIAMETER | 1.125 INCHES NOMINAL |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.406 INCHES NOMINAL |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |