5930-01-056-4699 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: Q1450W, Q1-4-50W, Q14C, Q-1/4/C, 142C949H01, 5930-01-056-4699, 01-056-4699, 5930010564699, 010564699
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 23, 1978 | 01-056-4699 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-056-4699
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| Q1-4-50W | 51434 | HARWIL CO |
| Q-1/4/C | 09TK8 | HARWIL CORP |
| 142C949H01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
Technical Data | NSN 5930-01-056-4699
| Characteristic | Specifications |
|---|---|
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACE ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +0.12 TO +8.00 ACTUATION POINT GALLONS PER MINUTE |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW |
| CONTACT STIMULUS RATING | ACAAM4.50 ACTUATION POINT MAXIMUM |
| OPERATING TEMP RATING | 180.0 DEG FAHRENHEIT MAXIMUM |
| TERMINAL TYPE | QUICK DISCONNECT, MALE |
| MOUNTING METHOD | INLET CONNECTION AND OUTLET CONNECTION |
| END ITEM IDENTIFICATION | AIR ROUTE SURVEILLANCE RADAR 3, (ARSR3) |