NSN 5930-01-058-0851
Part Details | PRESSURE SWITCH
5930-01-058-0851 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M939530KCCB, M9395/30-KCCB, MILDTL939530, MIL-DTL-9395/30, 6565209022115, 65652-09022-115, 5930-01-058-0851, 01-058-0851, 5930010580851, 010580851
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAR 22, 1978 | 01-058-0851 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-058-0851
Part Number | Cage Code | Manufacturer |
---|---|---|
M9395/30-KCCB | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-DTL-9395/30 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
65652-09022-115 | 78286 | SIKORSKY AIRCRAFT CORPORATIONDBA SIKORSKY |
Technical Data | NSN 5930-01-058-0851
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 3.700 INCHES NOMINAL |
BODY DIAMETER | 1.740 INCHES MAXIMUM |
OVERALL DIAMETER | 1.740 INCHES MAXIMUM |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BB350.00 ACTUATION POINT MAXIMUM AND BB275.00 DEACTUATION POINT MAXIMUM AND BB75.00 DIFFERENTIAL POINT MAXIMUM |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | CLAMP |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
TEST DATA DOCUMENT | 81349-MIL-DTL-9395 TO 30 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL-DTL-9395 TO 30 GOVERNMENT SPECIFICATION |
SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |