Part Details | THERMOSTATIC SWITCH
5930-01-061-9762 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 1104150325, 11041-50-325, ME01700100004, 5930-01-061-9762, 01-061-9762, 5930010619762, 010619762
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 07, 1978 | 01-061-9762 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-01-061-9762
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 11041-50-325 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
| ME01700100004 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 5930-01-061-9762
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 4 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 1.190 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.526 INCHES NOMINAL |
| BODY DIAMETER | 0.640 INCHES MAXIMUM |
| BODY HEIGHT | 0.350 INCHES MINIMUM AND 0.395 INCHES MAXIMUM |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADC DEACTUATION POINT AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | ACAAE13.00 ACTUATION POINT MAXIMUM AND ADAAE6.00 DEACTUATION POINT AND AKAAE7.00 DIFFERENTIAL POINT |
| MEDIA FOR WHICH DESIGNED | GAS |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | TURRET |
| MOUNTING METHOD | BRACKET AND SLOT AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.133 INCHES MINIMUM AND 0.147 INCHES MAXIMUM |
| MOUNTING SLOT WIDTH | 0.133 INCHES MINIMUM AND 0.147 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.930 INCHES MINIMUM AND 0.944 INCHES MAXIMUM |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |