NSN 5930-01-069-8605

Part Details | PRESSURE SWITCH

5930-01-069-8605 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: F757902, F-75790-2, 158F432, 158F43-2, 1204679002, 1204679-002, 1204679002, 1204679-002, 52714842, 5271484-2, 5930-01-069-8605, 01-069-8605, 5930010698605, 010698605

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 27, 197801-069-860500206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-069-8605
Part Number Cage Code Manufacturer
F-75790-297424AMETEK INC.DBA AMETEK AEROSPACE & DEFENSE
158F43-298087ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S
1204679-00256232LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
1204679-00202769LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
5271484-253711NAVAL SEA SYSTEMS COMMAND
Technical Data | NSN 5930-01-069-8605
Characteristic Specifications
STYLE DESIGNATOR6 CYLINDRICAL W/FLANGE
OVERALL LENGTH3.260 INCHES NOMINAL
OVERALL HEIGHT3.290 INCHES NOMINAL
OVERALL WIDTH1.750 INCHES NOMINAL
BODY LENGTH1.920 INCHES NOMINAL
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITYADC DEACTUATION POINT AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAM0.80 ACTUATION POINT MAXIMUM AND AKAAM0.19 DIFFERENTIAL POINT
OPERATING TEMP RATING-60.0 DEG CELSIUS MINIMUM AND 65.0 DEG CELSIUS MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
PROOF PRESSURE150.00 POUNDS PER SQUARE INCH GAGE
TERMINAL TYPE CONNECTOR, RECEPTACLE
MOUNTING METHOD CLAMP
FEATURES PROVIDED ELECTRICAL BOX CONNECTOR
SENSING ELEMENT BURST PRESSURE300.00 POUNDS PER SQUARE INCH GAGE