NSN 5930-01-079-7407
Part Details | THERMOSTATIC SWITCH
5930-01-079-7407 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 61256703, 612567-03, A19EAF2, 5930-01-079-7407, 01-079-7407, 5930010797407, 010797407
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUL 11, 1979 | 01-079-7407 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-079-7407
Part Number | Cage Code | Manufacturer |
---|---|---|
612567-03 | 98076 | BFM TRANSPORT DYNAMICS CORP |
A19EAF2 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
Technical Data | NSN 5930-01-079-7407
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 6 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 16.120 INCHES NOMINAL |
OVERALL HEIGHT | 4.400 INCHES NOMINAL |
OVERALL WIDTH | 2.150 INCHES NOMINAL |
BODY LENGTH | 1.810 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +30.00 TO +110.00 ACTUATION POINT DEGREES FAHRENHEIT AND +30.00 TO +110.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB WITH SCALE AND EXTERNAL DEACTUATION POINT KNOB WITH SCALE |
OPERATING TEMP RATING | 30.0 DEG FAHRENHEIT MINIMUM AND 140.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CAPILLARY TUBE LENGTH | 12.5 INCHES NOMINAL |
BULB LENGTH | 4.870 INCHES NOMINAL |
BULB DIAMETER | 1.250 INCHES NOMINAL |
TERMINAL TYPE | SCREW |
MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.940 INCHES MINIMUM AND 4.060 INCHES MAXIMUM |