NSN 5930-01-122-2506

Part Details | THERMOSTATIC SWITCH

5930-01-122-2506 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 3530994, 353099-4, 3530994, 353099-4, 3530994, 353099-4, 4391659, 4391-6-59, C423916, C42391-6, 5930-01-122-2506, 01-122-2506, 5930011222506, 011222506

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59NOV 18, 198101-122-250600451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-01-122-2506
Part Number Cage Code Manufacturer
353099-454X10RAYTHEON COMPANYDBA RAYTHEON
353099-449956RAYTHEON COMPANYDBA RAYTHEON
353099-43B150RAYTHEON COMPANYDBA RAYTHEON
4391-6-5982647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
C42391-682647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
Technical Data | NSN 5930-01-122-2506
Characteristic Specifications
STYLE DESIGNATOR4 CYLINDRICAL W/FLANGE
OVERALL LENGTH1.875 INCHES NOMINAL
OVERALL HEIGHT1.078 INCHES NOMINAL
BODY DIAMETER1.234 INCHES NOMINAL
BODY HEIGHT0.688 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAE75.00 ACTUATION POINT NOMINAL AND AE60.00 DEACTUATION POINT NOMINAL AND AE15.00 DIFFERENTIAL POINT NOMINAL
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.172 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.469 INCHES NOMINAL
FEATURES PROVIDED HERMETICALLY SEALED CASE
END ITEM IDENTIFICATIONHULL OBRP