NSN 5930-01-135-7335
Part Details | PRESSURE SWITCH
5930-01-135-7335 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M939531NHNEN, M9395/31-NHNEN, MILS939531, MIL-S-9395/31, 5930-01-135-7335, 01-135-7335, 5930011357335, 011357335
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 30, 1982 | 01-135-7335 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-135-7335
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M9395/31-NHNEN | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-S-9395/31 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-01-135-7335
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 2.500 INCHES MINIMUM AND 3.000 INCHES MAXIMUM |
| BODY DIAMETER | 0.890 INCHES MAXIMUM |
| OVERALL DIAMETER | 0.890 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ADC DEACTUATION POINT AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | ACABB800.00 ACTUATION POINT MAXIMUM AND ADABB500.00 DEACTUATION POINT AND AKABB300.00 DIFFERENTIAL POINT |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | CLAMP |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL--9395 TO 31 GOVERNMENT SPECIFICATION |
| SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |