NSN 5930-01-137-0009

Part Details | PRESSURE SWITCH

5930-01-137-0009 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 66072112, 6607-2-112, R66072112, R6607-2-112, 5930-01-137-0009, 01-137-0009, 5930011370009, 011370009

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 19, 198201-137-000900206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-137-0009
Part Number Cage Code Manufacturer
6607-2-11202750EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION
R6607-2-11202750EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION
Technical Data | NSN 5930-01-137-0009
Characteristic Specifications
OVERALL LENGTH3.250 INCHES MAXIMUM
OVERALL DIAMETER1.390 INCHES MAXIMUM
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS DECREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGBD16.50 ACTUATION POINT NOMINAL AND BD18.50 DEACTUATION POINT NOMINAL AND BD2.00 DIFFERENTIAL POINT NOMINAL
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDQ$DADF
PROOF PRESSURE75.00 POUNDS PER SQUARE INCH GAGE
TERMINAL TYPE CONNECTOR, RECEPTACLE
MOUNTING METHOD CLAMP
FEATURES PROVIDED ELECTRICAL BOX CONNECTOR
END ITEM IDENTIFICATIONVARIOUS