NSN 5930-01-226-0897
Part Details | THERMOSTATIC SWITCH
5930-01-226-0897 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: B039020, B039-020, E55AE21BC9236, E55A-E21BC-9236, E55AE21BC, E55A-E21BC, 5930-01-226-0897, 01-226-0897, 5930012260897, 012260897
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 12, 1986 | 01-226-0897 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-01-226-0897
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| B039-020 | 71228 | C H BULL CO |
| E55A-E21BC-9236 | 88234 | UNITED ELECTRIC CONTROLS COMPANY |
| E55A-E21BC | 88234 | UNITED ELECTRIC CONTROLS COMPANY |
Technical Data | NSN 5930-01-226-0897
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 2 RECTANGULAR |
| OVERALL LENGTH | 4.312 INCHES NOMINAL |
| OVERALL HEIGHT | 4.688 INCHES NOMINAL |
| OVERALL WIDTH | 2.125 INCHES NOMINAL |
| BODY LENGTH | 4.156 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACB ACTUATION POINT NOT ADJUSTABLE AND ADB DEACTUATION POINT |
| CONTACT ADJUSTMENT RANGE | -20.00 TO +65.00 ACTUATION POINT DEGREES CELSIUS AND -20.00 TO +65.00 DEACTUATION POINT DEGREES CELSIUS |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB WITH SCALE AND EXTERNAL DEACTUATION POINT KNOB WITH SCALE |
| OPERATING TEMP RATING | 200.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| CAPILLARY TUBE LENGTH | 72.0 INCHES NOMINAL |
| BULB LENGTH | 6.906 INCHES NOMINAL |
| BULB DIAMETER | 0.688 INCHES MAXIMUM |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | BRACKET AND THREADED HOLE |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.750 INCHES NOMINAL |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WEATHERPROOF |