NSN 5930-01-354-6684
Part Details | THERMOSTATIC SWITCH
5930-01-354-6684 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 13229E1289, 4E664, 701054561, 701-0545-61, 2E847, TC109010, TC109-010, TC109, 5930-01-354-6684, 01-354-6684, 5930013546684, 013546684
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAR 04, 1992 | 01-354-6684 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-01-354-6684
Part Number | Cage Code | Manufacturer |
---|---|---|
13229E1289 | 97403 | CECOM LR CENTER |
4E664 | 1LXT3 | GRAINGER INDUSTRIAL SUPPLY |
701-0545-61 | 0AK83 | HIGHLAND ENGINEERING, INC. |
2E847 | 16115 | PECO, INC.DBA PECO MANUFACTURING |
TC109-010 | 16115 | PECO, INC.DBA PECO MANUFACTURING |
TC109 | 16115 | PECO, INC.DBA PECO MANUFACTURING |
Technical Data | NSN 5930-01-354-6684
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 0 RECTANGULAR |
OVERALL LENGTH | 7.000 INCHES NOMINAL |
OVERALL HEIGHT | 2.875 INCHES NOMINAL |
OVERALL WIDTH | 3.500 INCHES NOMINAL |
BODY LENGTH | 5.875 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +40.00 TO +100.00 ACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB WITH SCALE |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
CAPILLARY TUBE LENGTH | 5.000 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.375 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 6.219 INCHES NOMINAL |
SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
CRITICALITY CODE JUSTIFICATION | FEAT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND MOISTURE RESISTANT |
END ITEM IDENTIFICATION | 3K GPH ROWPU. |