NSN 5930-01-373-5000
Part Details | THERMOSTATIC SWITCH
5930-01-373-5000 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 90C019042, 90C01-9042, 444088 EL, TS2063, TS-2063, 5930-01-373-5000, 01-373-5000, 5930013735000, 013735000
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | APR 07, 1993 | 01-373-5000 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-01-373-5000
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 90C01-9042 | 10855 | CARRIER CORPORATION |
| 444088 EL | 19278 | DETROIT SWITCH, INC. |
| TS-2063 | 19278 | DETROIT SWITCH, INC. |
Technical Data | NSN 5930-01-373-5000
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 5.240 INCHES NOMINAL |
| OVERALL HEIGHT | 5.520 INCHES NOMINAL |
| OVERALL WIDTH | 2.680 INCHES NOMINAL |
| BODY LENGTH | 5.240 INCHES NOMINAL |
| BODY HEIGHT | 2.740 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 2 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACE ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +90.00 TO +165.00 ACTUATION POINT DYNES PER SQUARE CENTIMETER |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW |
| OPERATING TEMP RATING | 130.000 DEG CELSIUS NOMINAL |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
| CAPILLARY TUBE LENGTH | 180.000 INCHES NOMINAL |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.276 INCHES MINIMUM AND 0.286 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.240 INCHES NOMINAL |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.380 INCHES NOMINAL |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.380 INCHES NOMINAL |
| INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.380 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 5.240 INCHES NOMINAL |
| SHORTEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 5.180 INCHES NOMINAL |