NSN 5930-01-453-1582
Part Details | PRESSURE SWITCH
5930-01-453-1582 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: P74DA9600, P74DA-9600, 5930-01-453-1582, 01-453-1582, 5930014531582, 014531582
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 20, 1998 | 01-453-1582 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-453-1582
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| P74DA-9600 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
Technical Data | NSN 5930-01-453-1582
| Characteristic | Specifications |
|---|---|
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | ADE DEACTUATION POINT AND ACE ACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +8.00 TO +60.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +8.00 TO +60.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT POINTER WITH SCALE AND EXTERNAL DEACTUATION POINT POINTER WITH SCALE |
| CONTACT STIMULUS RATING | ACABB15.00 ACTUATION POINT MAXIMUM AND ADABB20.00 DEACTUATION POINT AND AKABB5.00 DIFFERENTIAL POINT |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | BRACKET |