NSN 5945-01-340-0604

Part Details | ELECTROMAGNETIC RELAY

5945-01-340-0604 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Alternate Parts: 87863871, 8786387-1, M3901618040P, M39016/18-040P, MILR3901618, MIL-R-39016/18, MILPRF3901618, MIL-PRF-39016/18, 10132691, 114DM44106, 114DM4-4106, 114DM4410L, 114DM4-410L, 5945-01-340-0604, 01-340-0604, 5945013400604, 013400604

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 07, 199101-340-060432512 ( RELAY, ELECTROMAGNETIC )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-340-0604
Part Number Cage Code Manufacturer
8786387-149671LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
M39016/18-040P81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-R-39016/1881349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-PRF-39016/1881349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
10132691A486GNIMIKKEISTOKESKUS NCB FINLAND
114DM4-410611532TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS
114DM4-410L11532TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS
Technical Data | NSN 5945-01-340-0604
Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
ARC QUENCHING METHOD AIR
COIL QUANTITY1
WINDING QUANTITY1
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH0.405 INCHES MAXIMUM
OVERALL WIDTH0.370 INCHES MAXIMUM
OVERALL HEIGHT0.280 INCHES MAXIMUM
FEATURES PROVIDED COIL VOLTAGE SUPPRESSION
SPECIAL FEATURESFAILURE RATE 0.1 PERCENT PER 10,000 CYCLES
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-R-39016 TO 18 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATIONFEAT
PURPOSE FOR WHICH DESIGNED GENERAL
CUBIC MEASURE0.042 CUBIC INCHES
FRAGILITY FACTOR MODERATELY RUGGED
STORAGE TYPE GENERAL PURPOSE WAREHOUSE