NSN 5950-00-497-8949

Part Details | POWER TRANSFORMER

5950-00-497-8949 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 2006, 17130451, 17-13045-1, 17130451, 17-13045-1, 5950-00-497-8949, 00-497-8949, 5950004978949, 004978949

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 08, 196900-497-894932496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-00-497-8949
Part Number Cage Code Manufacturer
200616157DYCO ELECTRONICS, INC
17-13045-180070LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
17-13045-104614TEXTRON SYSTEMS CORPORATIONDBA TEXTRON DEFENSE SYSTEMS
Technical Data | NSN 5950-00-497-8949
Characteristic Specifications
TERMINAL TYPE AND QUANTITY24 SOLDER STUD
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH2.625 INCHES MINIMUM AND 2.750 INCHES MAXIMUM
BODY HEIGHT3.624 INCHES MINIMUM AND 3.812 INCHES MAXIMUM
BODY WIDTH2.250 INCHES MINIMUM AND 2.375 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING; SIX SECONDARY WINDINGS,ALL SECONDARY VOLTAGE AND CURRENT IS AFTER RECTIFICATION
TEST DATA DOCUMENT80070-17-13045 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS