NSN 5950-01-067-0996

Part Details | POWER TRANSFORMER

5950-01-067-0996 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 20000303002, 20-000303-002, 2697, 20000303002, 20-000303-002, 5950-01-067-0996, 01-067-0996, 5950010670996, 010670996

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 25, 197801-067-099632496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-067-0996
Part Number Cage Code Manufacturer
20-000303-00212436BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION INC.
269716157DYCO ELECTRONICS, INC
20-000303-00296169ELECTRIC BOAT CORPORATION
Technical Data | NSN 5950-01-067-0996
Characteristic Specifications
TERMINAL TYPE AND QUANTITY10 TURRET
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH2.187 INCHES MINIMUM AND 2.312 INCHES MAXIMUM
BODY HEIGHT2.937 INCHES MINIMUM AND 3.125 INCHES MAXIMUM
BODY WIDTH1.874 INCHES MINIMUM AND 2.062 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURESTERMINALS 1 AND 4 ARE SPLIT TO MAKE TERMINALS 2 AND 3 ON THE PRIMARY WINDING
TEST DATA DOCUMENT06809-20-000303 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION MOISTURE RESISTANT AND VIBRATION RESISTANT