NSN 5950-01-154-4769
Part Details | REACTOR
5950-01-154-4769 A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).
Alternate Parts: 7109257106, 7109257-106, 3172A6, 7109257106, 7109257-106, 7109257006, 7109257-006, 3172A6, CLF514, 10132859, CLF514, 5950-01-154-4769, 01-154-4769, 5950011544769, 011544769
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAY 25, 1983 | 01-154-4769 | 00724 ( REACTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-154-4769
Part Number | Cage Code | Manufacturer |
---|---|---|
7109257-106 | 72149 | ELECTRONIC TRANSFORMER CORP.DIV ELECTRONIC TRANSFORMER |
3172A6 | 72149 | ELECTRONIC TRANSFORMER CORP.DIV ELECTRONIC TRANSFORMER |
7109257-106 | 93322 | GE AVIATION SYSTEMS LLCDBA GE AVIATION |
7109257-006 | 93322 | GE AVIATION SYSTEMS LLCDBA GE AVIATION |
3172A6 | 56232 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
CLF514 | 15634 | MAGNETIKA, INC. |
10132859 | A486G | NIMIKKEISTOKESKUS NCB FINLAND |
CLF514 | 80223 | UNITED TRANSFORMER CORPSUB OF OPT INDUSTRIES INC |
Technical Data | NSN 5950-01-154-4769
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 2 TURRET |
INDUCTANCE TYPE | FIXED |
INCLOSURE TYPE | OPEN |
OVERALL LENGTH | 0.700 INCHES MAXIMUM |
OVERALL DIAMETER | 0.534 INCHES MINIMUM AND 0.559 INCHES MAXIMUM |
FEATURES PROVIDED | TINNED WIRE LEADS |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TEST DATA DOCUMENT | 93322-7109257 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
END ITEM IDENTIFICATION | ACFT F-18 |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |