NSN 5950-01-167-4614

Part Details | POWER TRANSFORMER

5950-01-167-4614 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: M275418B, M27/54-18B, MILT2754, MIL-T-27/54, MILPRF2754, MIL-PRF-27/54, 5950-01-167-4614, 01-167-4614, 5950011674614, 011674614

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59NOV 29, 198301-167-461432496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-167-4614
Part Number Cage Code Manufacturer
M27/54-18B81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-T-27/5481349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-PRF-27/5481349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 5950-01-167-4614
Characteristic Specifications
TERMINAL TYPE AND QUANTITY5 FEED THRU
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH1.031 INCHES MINIMUM AND 1.093 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.969 INCHES MINIMUM AND 1.031 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-T-27 TO 54 GOVERNMENT SPECIFICATION
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION VIBRATION RESISTANT