NSN 5950-01-185-2315

Part Details | POWER TRANSFORMER

5950-01-185-2315 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 2722, WE3438, 7225701, 722570-1, WE3438, 5950-01-185-2315, 01-185-2315, 5950011852315, 011852315

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 26, 198401-185-231532496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-185-2315
Part Number Cage Code Manufacturer
272252463ELECTRO-NUMERICS INC.DIV CRA ENTERPRISES
WE343815634MAGNETIKA, INC.
722570-105869RAYTHEON COMPANYDBA RAYTHEON
WE343826543WEMS ELECTRONICSTRANSFORMER GROUP
Technical Data | NSN 5950-01-185-2315
Characteristic Specifications
TERMINAL TYPE AND QUANTITY4 TURRET
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH1.500 INCHES MAXIMUM
BODY HEIGHT1.380 INCHES MAXIMUM
BODY WIDTH1.250 INCHES NOMINAL
OVERALL HEIGHT1.690 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
MAXIMUM OPERATING TEMP105.0 DEG CELSIUS