NSN 5962-01-249-4951

Part Details | LINEAR MICROCIRCUIT

5962-01-249-4951 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Alternate Parts: LO3634, EHA12539883B, EHA1-2539/883B, HA125398, HA1-2539-8, 124187, 5962-01-249-4951, 01-249-4951, 5962012494951, 012494951

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 11, 198701-249-495131778 ( MICROCIRCUIT, LINEAR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5962-01-249-4951
Part Number Cage Code Manufacturer
LO363416236DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
EHA1-2539/883B64762ELANTEC INC
HA1-2539-834371INTERSIL CORPORATIONDIV NA
12418794271LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
Technical Data | NSN 5962-01-249-4951
Characteristic Specifications
DESIGN FUNCTION AND QUANTITY1 AMPLIFIER, OPERATIONAL, GENERAL PURPOSE
INPUT CIRCUIT PATTERN 2 INPUT
VOLTAGE RATING AND TYPE PER CHARACTERISTICACV35.0 VOLTS MAXIMUM
OPERATING TEMP RANGE-55.0 TO +125.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY14 PRINTED CIRCUIT
TERMINAL SURFACE TREATMENT SOLDER
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL CERAMIC AND GLASS
BODY LENGTH0.753 INCHES MINIMUM AND 0.785 INCHES MAXIMUM
BODY HEIGHT0.140 INCHES MINIMUM AND 0.170 INCHES MAXIMUM
BODY WIDTH0.265 INCHES MINIMUM AND 0.285 INCHES MAXIMUM
MAXIMUM POWER DISSIPATION RATING870.0 MILLIWATTS
STORAGE TEMP RANGE-65.0 TO +150.0 DEG CELSIUS
FEATURES PROVIDED HIGH SPEED AND HIGH SLEW RATE AND MONOLITHIC AND WIDEBAND
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3634
TEST DATA DOCUMENT96906-MIL-STD-883 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.).
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATIONZZZY