NSN 5962-01-575-0653
Part Details | DIGITAL MICROCIRCUIT
5962-01-575-0653 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".
Alternate Parts: AD8307AR, 91785588, 5962-01-575-0653, 01-575-0653, 5962015750653, 015750653
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUN 18, 2009 | 01-575-0653 | 31779 ( MICROCIRCUIT, DIGITAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5962-01-575-0653
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| AD8307AR | 24355 | ANALOG DEVICES, INC.DIV CORPORATE HEADQUARTERS |
| 91785588 | F6481 | THALES SA |
Technical Data | NSN 5962-01-575-0653
| Characteristic | Specifications |
|---|---|
| DESIGN FUNCTION AND QUANTITY | 1 AMPLIFIER, LOG |
| OPERATING TEMP RANGE | -40.0 TO +85.0 DEG CELSIUS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | LOW COST, DC TO 500 MHZ, 92 DB LOGARITHMIC AMPLIFIER |
| BODY LENGTH | 3.800 INCHES MINIMUM AND 4.000 INCHES MAXIMUM |
| BODY HEIGHT | 1.100 INCHES MINIMUM AND 1.650 INCHES MAXIMUM |
| BODY WIDTH | 4.800 INCHES MINIMUM AND 5.000 INCHES MAXIMUM |
| STORAGE TEMP RANGE | -65.0 TO +125.0 DEG CELSIUS |
| SPECIAL FEATURES | COMPLETE MULTISTAGE LOGARITMIC AMPLIFIER;92 DB DYNAMIC RANGE, -75 DBM TO +17 DBM TO -90 DBM USING MATCHING NETWORK;SINGLE SUPPLY OF 2.7 V MINIMUM AT 7.5 MA TYPICAL;DC TO 500 MHZ OPERATION, +/-1 DB LINEARITY;SLOPE OF 25 MV/DB, INTERCEPT OF -84 DBM;HIGHLY STABLE SCALING OVER TEMPERATURE;FULLY DIFFERENTIAL DC-COUPLED SIGNAL PATH;100 NS POWER-UP TIME |
| OVERALL LENGTH | 5.800 INCHES MINIMUM AND 6.200 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.350 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
| END ITEM IDENTIFICATION | CONVERSION OF SIGNAL LEVEL TO DECIBEL FORM;TRANSMITTER ANTENNA POWER MEASUREMENT;RECEIVER SIGNAL STRENGTH INDICATION (RSSI);LOW COST RADAR AD SONAR SIGNAL PROCESSING;NETWORK AND SPECTRUM ANALYZERS (TO 120 DB);SIGNAL LEVEL DETERMINATION DOWN TO 20 HZ;TRUE DECIBEL AC MODE FPR MULTIMETERS |