NSN 5970-00-057-1888
Part Details | ELECTRICAL INSULATION SLEEVING
5970-00-057-1888 A rigid or flexible tubing having uniform inside and outside diameters in the overall length. It is specifically designed to prevent any undesirable flow of current between conductors and other objects. Includes shrinkable type tubing, items in bulk and in specific fabricated lengths (cut to size). Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (as modified); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; and TUBING, NONMETALLIC.
Alternate Parts: G145024522, G145-024-522, AMS3653, 5970-00-057-1888, 00-057-1888, 5970000571888, 000571888
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUN 08, 1967 | 00-057-1888 | 00867 ( INSULATION SLEEVING, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
NONSHRINKABLE
Cross Reference | NSN 5970-00-057-1888
Part Number | Cage Code | Manufacturer |
---|---|---|
G145-024-522 | 88818 | KEARFOTT CORPORATIONDBA KEARFOTT |
AMS3653 | 81343 | SOCIETY OF AUTOMOTIVE ENGINEERS INC |
Technical Data | NSN 5970-00-057-1888
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | NONSHRINKABLE |
WALL THICKNESS | 0.020 INCHES NOMINAL |
INSIDE DIAMETER | 0.204 INCHES MINIMUM AND 0.224 INCHES MAXIMUM |
COLOR | NATURAL |
FLEXIBILITY | FLEXIBLE |
TEMP RATING | 260.0 DEG CELSIUS |
MINIMUM TENSILE STRENGTH | 2500 POUNDS PER SQUARE INCH |
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 16000.0 |
SPECIFICATION/STANDARD DATA | 81343-MS3653 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
NONDEFINITIVE SPEC/STD DATA | 4AWG SIZE |