NSN 5970-00-059-5182
Part Details | SPECIAL PURPOSE ELECTRICAL INSULATION SLEEVING
5970-00-059-5182 A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.
Alternate Parts: 6015EECN, 342A0345, 342A034-5, 130303882, 13030388-2, 5970-00-059-5182, 00-059-5182, 5970000595182, 000595182
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1961 | 00-059-5182 | 61626 ( INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE ) |
REFERENCE DRAWINGS & PICTURES
TRANSITION-45 DEGREES
Cross Reference | NSN 5970-00-059-5182
Part Number | Cage Code | Manufacturer |
---|---|---|
6015EECN | 06090 | TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION |
342A034-5 | 06090 | TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION |
13030388-2 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 5970-00-059-5182
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | TRANSITION-45 DEGREES |
MATERIAL | RUBBER CHLOROPRENE CLASS CR |
COLOR | BLACK |
FLEXIBILITY | FLEXIBLE |
TEMP RATING | -55.0 DEG CELSIUS AND 150.0 DEG CELSIUS |
MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 200.0 |
ENVIRONMENTAL PROTECTION | |
RELIABILITY INDICATOR | NOT ESTABLISHED |