NSN 5970-01-183-8663

Part Details | ELECTRICAL INSULATION SLEEVING

5970-01-183-8663 A rigid or flexible tubing having uniform inside and outside diameters in the overall length. It is specifically designed to prevent any undesirable flow of current between conductors and other objects. Includes shrinkable type tubing, items in bulk and in specific fabricated lengths (cut to size). Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (as modified); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; and TUBING, NONMETALLIC.

Alternate Parts: SCX15112008, SC-X15112-008, NTFR10SP, NTFR-1-0-SP, NTFR 1 INCH BLACK, NTFR 1BLACK, NT-FR 1BLACK, 5970-01-183-8663, 01-183-8663, 5970011838663, 011838663

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 11, 198401-183-866300867 ( INSULATION SLEEVING, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

SHRINKABLE

Cross Reference | NSN 5970-01-183-8663
Part Number Cage Code Manufacturer
SC-X15112-00801417GENERAL DYNAMICS LAND SYSTEMS INC.DBA GENERAL DYNAMICS LAND SYSTEMS
NTFR-1-0-SP06090TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION
NTFR 1 INCH BLACK06090TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION
NT-FR 1BLACK06090TE CONNECTIVITY CORPORATIONDBA RAYCHEM PRODUCT DIVISION
Technical Data | NSN 5970-01-183-8663
Characteristic Specifications
STYLE DESIGNATOR SHRINKABLE
EXPANDED INSIDE DIAMETER1.000 INCHES MINIMUM
RECOVERED INSIDE DIAMETER0.570 INCHES MAXIMUM
RECOVERED WALL THICKNESS0.050 INCHES MINIMUM AND 0.090 INCHES MAXIMUM
MATERIAL RUBBER
COLOR BLACK
FLEXIBILITY FLEXIBLE
HEAT SHRINKAGE RATING IN PERCENT43.0
TEMP RATING-70.0 DEG CELSIUS AND 121.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS300.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT
RELIABILITY INDICATOR NOT ESTABLISHED