NSN 5970-01-306-0622

Part Details | ELECTRICAL INSULATION SLEEVING

5970-01-306-0622 A rigid or flexible tubing having uniform inside and outside diameters in the overall length. It is specifically designed to prevent any undesirable flow of current between conductors and other objects. Includes shrinkable type tubing, items in bulk and in specific fabricated lengths (cut to size). Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (as modified); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; and TUBING, NONMETALLIC.

Alternate Parts: M2305343039, M23053/4-303-9, MILI230534, MIL-I-23053/4, M2305343039, M23053/4-303-9, AMSDTL230534, AMS-DTL-23053/4, 5970-01-306-0622, 01-306-0622, 5970013060622, 013060622

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 16, 198901-306-062200867 ( INSULATION SLEEVING, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

SHRINKABLE

Cross Reference | NSN 5970-01-306-0622
Part Number Cage Code Manufacturer
M23053/4-303-981349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-I-23053/481349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
M23053/4-303-981343SOCIETY OF AUTOMOTIVE ENGINEERS INC
AMS-DTL-23053/481343SOCIETY OF AUTOMOTIVE ENGINEERS INC
Technical Data | NSN 5970-01-306-0622
Characteristic Specifications
STYLE DESIGNATOR SHRINKABLE
EXPANDED INSIDE DIAMETER0.470 INCHES MINIMUM
RECOVERED INSIDE DIAMETER0.160 INCHES MAXIMUM
RECOVERED WALL THICKNESS0.056 INCHES MINIMUM AND 0.084 INCHES MAXIMUM
COLOR WHITE
FLEXIBILITY FLEXIBLE
HEAT SHRINKAGE RATING IN PERCENT66.0
TEMP RATING-55.0 DEG CELSIUS AND 110.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS300.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT
SPECIAL FEATURESMELTABLE INNER WALL 0.030 IN. THK